Cause of defect
|
Way of elimination
|
The electric motor does not work
|
Wires are damaged or connections of wires were oxidised
|
Check up and restore connections. Replace the damaged wires
|
Has fused safety lock F18 in the block of safety locks
|
Replace a safety lock
|
The heater switch is damaged - pressure does not move for the weekend switch plugs
|
Check up the switch, if necessary replace new
|
Lag or deterioration of brushes of the electric motor, breakage in a winding of an anchor or collector pollution
|
Check up the electric motor, repair or replace
|
Short circuit on "weight" of a winding of an anchor - at inclusion
The electric motor burns down a safety lock
|
Replace the electric motor
|
The electric motor works only on one speed
|
Wires are damaged or connections of wires were oxidised
|
Check up and restore connections. Replace the damaged wires
|
The heater switch is damaged
|
Check up the switch, if necessary replace new
|
Has fused the additional resistor
|
Replace the additional resistor
|
The electric motor anchor rotates slowly
|
Pollution or collector oxidation, deterioration of brushes
|
Smooth out a collector, replace brushes
|
Mezhvitkovoe short circuit in an anchor winding
|
Replace the electric motor
|
Jamming of a shaft of an anchor in bearings
|
Replace the electric motor
|