9-18-ehlektrodvigatel-ventilyatora-sistemy-okhlazhdeniya-dvigatelya.html
9.18. The electric motor of the fan of system of cooling of the engine Features of a design
Fans of system of cooling are resulted by two electric motors of a direct current with excitation from constant magnets. The controller of a control system of the engine operates work of fans. Electric motors of fans of system of cooling of the engine do not require service. In case of failure replace their new. For check of serviceability of electric motors take advantage of the data from tab. 9.6.
|
Fig. 9.24. The scheme of inclusion of electric motors of fans of system of cooling: 1 – the right electric motor of the fan of system of cooling of the engine; 2 – the additional relay; 3 – a safety lock; 4 – the additional resistor; 5 – the relay of inclusion of the right electric motor; 6 – the left electric motor of the fan of system of cooling of the engine; 7 – the relay of inclusion of the left electric motor; And – to the plug «–» the storage battery; In – to the main relay; With – to the plug «+» the storage battery
|
Table 9.6 of Dannnye for check of electric motors of fans of system of cooling of the engine
Checked indicator
|
Value
|
Nominal frequency of rotation of a shaft at electric motor loading крыльчаткой, mines-1
|
2600-2800
|
Consumed current strength at the specified loading and frequency of rotation, And, no more
|
25
|
Electric motor replacement
The key «on 10» is required to you.
1. Disconnect a wire from the plug "minus" of the storage battery.
|
2. Remove electrofans in gathering with a casing (Replacement of a radiator and electrofans of system of cooling »see«).
|
|
|
3. Turn away a nut and remove крыльчатку.
|
4. Take a pin from an electric motor shaft.
|
|
|
5. Turn away three nuts of fastening of the electric motor to a casing.
|
6. Remove the holder of wires.
|
|
7. Remove the electric motor.
|
8. Establish the electric motor and крыльчатку in an order, the return to removal.
|
|